Unregulated Fullwave Bridge Rectifier with Filtering
Previous Article in this series The prerequisite for this article can be read here: Unregulated Fullwave Center-Tapped Filtered Power Supply Given Given: Vpri = 120v & 60Hz, Turns ratio = 4:1, C1 = 10uF, RL = 10K Ohms Calculate Primary Voltage Start by converting the primary RMS voltage to Peak voltage.$$Vpeak_{Primary}=frac{V_{RMS}}{0.707}$$$$Vpeak_{Primary}=frac{120V_{RMS}}{0.707}$$$$Vpeak_{Primary}=169.731vp$$ Primary Peak to Peak …